TM 11-5821-333-30
6-31, TEST ADAPTER CONNECTORS, Continued
d. Replacement of Connector P1, P2, P3, P6, P7, P8, and P9
These are the connectors connected to the reference rt, reference rcu, and reference dra.
This task covers: a. Removal
b. Installation
INITIAL SETUP
Tools
Tool Kit, Electronic Equipment, TK-105/G
Pin removal/installation tool included with replacement connector
Equipment Conditions
Interconnecting device removed from chest (paragraph 6-22).
REMOVAL
INSTALLATION
1.
2.
3.
Loosen two captive screws on strain relief on
1.
rear of connector.
Loosen strain relief by rotating nut counter-
2.
clockwise, and slide free of connector.
3.
Tag wires, and remove pins from connector
using tool supplied with replacement connec-
tor.
4.
5.
Inspect connector strain relief for damage, If
damaged, obtain replacement.
Place strain relief on cable.
Using tool supplied with replacement con-
nector, insert pins into connector.
Slide strain forward and engage connector.
Tighten coupling nut by rotating clockwise.
Tighen two captive screws on strain relief.
6-199