TM 11-5821-333-30
6-37. TEST ADAPTER LAMP TEST CCA (A1)
This task covers: a. R e m o v al
b. Installation
Tools
Tool Kit, Electronic Equipment, TK-100/G
Tool Kit, Electronic Equipment, TK-105/G
Equipment Conditions
Interconnecting device removed from chest (paragraph 6-22).
CAUTION
Static electricity and stray voltages can damage the CCA. Use an antistatic pad on
the work surface and attach a grounded wrist strap to self before handling CCA.
1.
2.
3.
4.
Disconnect P5 and P1O (1) from lamp test
CCA (2).
Fully loosen and remove four screws (3).
Iockwashers, and flat washers securing CCA
to four aluminum spacer sleeves.
Discard Iockwashers.
Remove lamp test CCA.
INSTALLATION
1. Thread and tighten four screws (3) with flat
washers and Iockwashers through good CCA
and into spacer sleeves.
2. Connect P5 and P1O (1) to CCA (2).
6-211