TM 11-5821-333-30
6-36. TEST ADAPTER RELAYS
This procedure covers replacement of relays K1, K2, and K3.
This task covers: a. Removal
b. Installation
INITIAL SETUP
Tools
Expendable Supplies
Tool Kit, Electronic Equipment, TK-100/G
Tiedown Straps
Tool Kit, Electronic Equipment, TK-105/G
Solder
Equipment Conditions
Test adapter removed from interconnecting device (paragraph 6-28).
REMOVAL
INSTALLATION
1.
2.
3.
4.
5.
6.
Using diagonal cutting pliers, cut and remove
1.
any tiedown straps that interfere with desold-
ering.
2.
Tag wires soldered to relay, and desolder.
Tag rf cables (1) and wires (2) connected to
3.
relay (3).
4.
Disconnect rf cables.
5.
Loosen and remove two screws, washers,
Iockwashers, and nuts (4) securing relay.
Discard Iockwashers.
Remove relay.
Thread two screws through relay, washers,
Iockwashers, and nuts (4). Tighten.
Connect rf cables (1) to correct coaxial con-
nectors on relay (3).
Solder wires to relay.
Remove wire tags,
Replace any tiedown straps removed.
6-210