TM 11-5821-333-30
6-33. TEST ADAPTER TEST POINTS
This task covers: a. Removal
b. Installation
Tools
Expendable Supplies
Tool Kit, Electronic Equipment, TK-100/G
Tiedown Straps
Tool Kit, Electronic Equipment, TK-105/G
Solder
Interconnecting device removed from chest (paragraph 6-22).
1.
2.
3.
4.
5.
Cut and remove any tiedown straps that may
interfer with resoldering.
Unsolder wire (1) from test point (2).
Loosen and remove hex nut (3) and lock-
washer securing test point to front panel.
Pull test point out of front panel.
Get good test point.
1.
2.
3.
4.
Insert good test point in test adapter.
Thread and tighten hex nut (3) and lockwash-
er onto test point.
Solder wire (1) onto test point (2).
Replace any removed tiedown straps.
6-206