15.3 Special Requirements
a. The panel markings of certain controls on Audio Oscillator TS-382A/U differ from those used on other models. References to con-
trols in the charts apply to the TS-082B/U, TS-382D/U, TS-382E/U, and TS-382F/U. If the TS-382A/U is used to perform these tests,
use the control that corresponds to that given in the charts.
b. The AF-RF switch on Spectrum Analyzer TS-723A/U does not exist on the TS-723B/U or the TS-723C/U. The use of the TS-
723B/U or the TS723C/U for these tests is not affected by the omission of the AF-RF switch.
15.4 Modification Work Orders
There were no modification work orders in effect for this equipment as of the date of this Change. Any MWO'S pertaining to this equip-
ment that may be published since the date of this Change will be listed in DA Pam 310-4. MWO'S other than those classed URGENT
should not be reason for rejection.
15.5 Physical Tests and Inspection
a. Test Equipment and Materials. None.
b. Test Connections and Conditions. Make no connections to the AM1881/U during these tests.
c. Test Procedure.
Step
Test procedure
Performance standard
No.
Equipment under test control settings
Test equipment control settings
1
All switches should operate freely without
Controls may be in any posi-
None.
Check POWER and GAIN switches for
binding.
proper operation.
tion.
2
a. Connectors, indicator lamp, fuse terminal
a. Inspect all connectors, indicator lamp,
Same as above.
None.
boards, cords, and cover Plates should
fuse, terminal boards, cords, and cover
not be damaged to the extent of affect-
plates for damage, missing parts, or in-
ing proper operation or have missing
correct ratings.
parts or wrong fuse value. Fuse should
be 0.8 amp for 115V AC and 0.4 amp
for 230V AC operation.
b, There should be no dents punctures, or
b. Inspect entire amplifier for physical dam-
bent areas of a nature that would affect
age, such as dents, punctures, and bent
proper operation.
areas.
c. Surfaces originally painted should not show
c. Inspect amplifier for condition of finish
bare metal. Panel markings should be
and panel markings.
legible.
3
a. All tubes should be vertical, and snugly
None.
a. Check seating of all tubes and tube shields
Same as above.
seated. Shields should be in place, and
in their sockets.
in electrical contact with the chassis.
of overheating.
ing, or other evidence of excessive heat-
ing.
c. Capacitors should not show evidence of
c. Check all capacitors for evidence of leakage
leakage.