TM 11-5895-1090-34/TO 31 R2-2TSC-152
(3) Connect the equipment to a 120 +5 vac
source and turn on equipment.
each of the power supply volt TP's and GND on the test
fixture, and adjust each power supply to its appropriate
level as indicated below:
VOL T TP
ADJUSTMENTLEVEL
+ 15V
+ 15 +0.2 vdc
- 15V
- 15 +0.2 vdc
+ 14V
+ 14 +0.2 vdc
c.
Test and Troubleshooting Procedures.
Perform the procedures in table 4-7 to test and
troubleshoot a suspected faulty rf low power alarm
assembly. Always perform the procedures from the
beginning. When the steps of table 4-7 have been
performed with no abnormal indications, the rf low
power alarm can be returned to stock or normal
operation in the terminal. If an abnormal indication is
obtained during performance of the procedures, in-
structions to correct the problem are given in the
When the fault is
repaired, retest the rf low power alarm to confirm that it
measurements.
Figure 4-8. Component Location Diagram, Rf Low
Power Alarm Assembly A5.
4-12