TM 11-5821-333-30
6-23. REFERENCE RT
This task covers: a, Removal
b. Installation
INITIAL SETUP
Tools
Tool Kit, Electronic Equipment, TK-105/G
Equipment Conditions
Interconnecting device removed from chest (paragraph 6-22).
REMOVAL
1. Disconnect rt cable W3 (1), connector PI (2)
and connector P2 (3) from rear of reference
rt.
2. Loosen six Dzus fasteners (4) securing refer-
ence rt (5) to test adapter (6).
3. Pull reference rt out of test adapter. Get good
rt.
INSTALLATION
1.
2.
3.
Position good rt into RT slot of test adapter.
Tighten six Dzus fasteners (4) securing refer-
ence rt (5) to test adapter (6).
Connect rf cable W3 (1), connector P1 (2),
and connector P2 (3) to rear of reference rt.
CAUTION
Be sure cable W3 is connected to J3, not to J4 or
6-185