TM 11-5821-333-30
6-210 REPAIR PROCEDURES
The following instructions apply to all repair tasks unless otherwise noted in the procedure,
1.
Begin procedure with ac and dc power supplies turned off and disconnected from the test adapter,
2.
Disconnect any other external cable connected to the test adapter,
3.
Inspect maintenance group, Repair any obvious physical damage,
4.
Repair fault identified by troubleshooting.
5.
Verify fault repair by performing operational check. If any wiring is repaired, verify the repair immedi-
ately using the DMM.
WARNING
l Remove power from maintenance group before repair. Serious burns or electrical shock can
result from contact with exposed electrical wires or connectors.
l Isopropyl alcohol is flammable and toxic to skin, eyes, and respiratory tract. Avoid skin and
eye contact. Good general ventilation is normally adequate, Keep away from open flames or
other sources of ignition.
6-22. INTERCONNECTING DEVICE
This task covers: a. Removal
b. Installation
INITIAL SETUP
Tools
Tool Kit, Electronic Equipment, TK-105/G
REMOVAL
1. Fully loosen 12 captive screws (1) securing
interconnecting device (2) to maintenance
group chest (3).
2. Lift and remove interconnecting device from
maintenance group chest.
INSTALLATION
1.
Position interconnecting device (2) in chest
(3).
2. Thread and tighten 12 captive screws (1).
6-184