TM 11-5821-333-305-6. GENERALMaintenance shouldSection IV. MAINTENANCEbe performed in the following sequence.PROCEDURESa. Inspection. Determine if the mounting base is damaged or incomplete. If a component is damaged ormissing, replace it.b. Troubleshooting. Done on a bad MT-6373 mounting base noted in operation or during operational check.Do not troubleshoot good equipment.c. Repair. The repair procedures are used to restore a faulty mounting base to serviceable/operable condi-tion, Repair is by replacement of bad item.5-7. INSPECTIONMany faults can be found by inspection. If any are found, replace bad item. The following chart can be used as aguide.ITEMREMARKSTray assemblyNo dents, cracks, rust, or bends.CablesNo broken wires or damaged insulation.ConnectorsNo cracks, No broken or missing pins.Handle assemblyNo bends, rust, or missing parts.5-8.a.b.5-9.REPAIRGeneral Instructions. The following instructions apply to all repair tasks.1. Remove any cables connected to the mounting base.2. Inspect the mounting base for damage. Repair any obvious physical damage.Repair PrecautionsWARNINGRemove power from MT-6373 mounting base before repair. Serious burns or electrical shockcan result from contact with exposed electrical wires or connectors.MT-6373 MOUNTING BASEThis task covers:a. Disassemblyb. AssemblyINITIAL SETUPToolsExpendable SuppliesTool Kit, Electronic Equipment, TK-105/GCotton Swab and AlcoholReferencesFigure 5-2 shows parts location.5-3
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business