TM 11-5821-333-30
6-41. TEST ADAPTER CAPACITORS C1 AND C2
This paragraph gives the procedure for replacing resistors C1 and C2. C1 and C2 are mounted on the voltage
regulator U1 receptacle.
This task covers: a. Removal
b. Installation
INITIAL SETUP
Tools
Expendable Supplies
Tool Kit, Electronic Equipment, TK-100/G
Insulated Sleeving
Tool Kit, Electronic Equipment, TK-105/G
Solder
Equipment Conditions
Interconnecting device removed from chest (paragraph 6-22).
REMOVAL
1.
Unsolder both leads of bad capacitor.
2. For capacitor C2 only: loosen hex nut (1) se-
curing loop clamp (2) to voltage regulator
socket (3).
3. Remove bad capacitor.
INSTALLATION
1.
Cut lengths of insulated sleeving to cover
leads of capacitor.
2. For capacitor C2 only: slide capacitor into
loop clamp (2) on socket (3) with (+) lead
oriented toward pin 2 of U1 . Tighten hex nut
(1) securing loop clamp to socket.
3. Solder good capacitor into place.
6-218