TM 11-5821-333-303-10. TROUBLESHOOTING FLOWCHARTS. ContinuedCHART 8Homing Operate Voltage Missing (Sheet 1 of 2)HOMING OPERATEVOLTAGE MISSINGNOTE1. CONNECT EQUIPMENT ASSHOWN IN FIG 3-7.2. SET TEST ADAPTER:TEST EQPTINPUTEXT3. SET UUT:FUNCTIONSQ ON4. READ DMM WITH X1PROBE AT XA4-1.See figure FO-11 forlocation of test points.1. REMOVE INTERFACE (A2)AND PROCESSOR (A3)MODULES.2. REMOVE FOUR SCREWSSECURING CONTROLPANEL (A1) TO CHASSIS(A5) AND LAY FOR-WARD.3. READ DMM WITH X1PROBE AT MODE SWITCHS2-7.3-49