TM 11-5821-333-30
3-10. TROUBLESHOOTING FLOWCHARTS. Continued
CHART 5
Fails Self-Test at Preset 1, 2, 3, 4, 5, 6, or CUE
NOTE
1. SET TEST ADAPTER:
DC
OFF
2. DISCONNECT TEST
CABLE W3 FROM UUT.
3. REMOVE CONTROL
PANEL (A1) FROM UUT.
4. USE DMM AND TEST
LEADS TO MEASURE RE-
SISTANCE BETWEEN
W2P1 AND PRESET
SWITCH (S4). SEE
TABLE.
See figure FO-11 for
location of test points.
PRESET
MEASURE
FAILURE
BETWEEN
1
P1-8
S4-2
2
P1-2
S4-3
3
P1-9
S4-4
4
P1-3
S4-5
5
P1-11
S4-6
P1-10
S4-7
P1-4
6
CUE
S4-8
3-46