TM 11-5821-333-30
2-23. OPERATIONAL CHECK. Continued
ACTION
RESPONSE
Step 11. AN/ARC-201A(V) FILL CHECKS
a.
b.
c.
Set rf signal generator output to -120 dBm.
a. No response.
Set S1 on test adapter to OFF.
b. No response.
Set uut switches:
FUNCTION
LD
PRESET
1
MODE
FH
c. Response:
If not, go to chart 19.
Set ECCM fill device function switch to OFF.
d. No response.
d.
e.
f.
g.
h.
e. No response.
Connect fill device to uut.
Set fill device to hopset.
f. No response,
Set fill device function switch to ON.
g. No response,
Press LOAD.
h, Response:
(n = 0-9)
If not, go to chart 20.
i.
Response:
i.
Press STO.
If not, ECCM module (A3) is bad.
j.
Display reads Sto 1, then blinks. If not,
ECCM module (A3) is bad.
k. No response.
1.
No response.
m. No response.
n. No response.
o. No response.
j.
With Sto _ in display, press 1.
k. Set fill device function switch to OFF.
1.
Disconnect fill device.
m. Load same hopset in ref rt, preset 1.
n. Press FREQ key on ref rt.
o. Turn off and disconnect fill device.