TM 11-5821-333-30
2-23. OPERATIONAL CHECK. Continued
ACTION
RESPONSE
Step 10. AN/ARC-201(V) FILL CHECKS. Continued
h. Press H-Ld/0.
h.
i.
Set uut FUNCTION switch to LD.
j.
Set fill device select switch to hopset.
k. Press H-Ld/0.
1.
Press Sto/ENT.
m. With Sto _ in display, press 1.
n. Set fill device function switch to OFF.
o. Disconnect fill device.
p. Load same TRANSEC variable and same
hopset into ref rt, preset 1.
q, Press FREQ key on ref rt.
r.
Turn off and disconnect fill device.
i.
j.
k.
1.
m.
n.
o.
p.
q.
r.
Response:
If not, go to chart 20.
No response.
No response.
Response:
If not, ECCM module (A3) is bad.
Response:
If not, ECCM module (A3) is bad.
Display reads Sto 1. then blinks, If not,
ECCM module (A3) is bad.
No response.
No response,
No response,
No response,
No response.
2-26