TM 11-5820-801-30
(3) Remove cable plug W2P2 from 2A1J1.
two pump waveguide interface flanges removed in (1)
(4) Slide open the four mounting slide clips
and (2) above.
c. Second Stage Paramp Module 2A 2. Refer to
that hold 2A1 in 2A5.
(5) Lift out Pump Source Module 2A1.
(6) To reinstall 2A1, place the module in 2A5.
(1) Remove Waveguide Filter Module 2A4 (a above).
Slide closed the four mounting slide clips, reconnect
W2P2 to 2A1J1 and replace the eight cap screws in the
3-33