Publication
Title
assembled into identifiable lots. Each lot shall, as far as
TB SIG 355-4
Depot Inspection Standard for
practicable, consist of units of product of a single type,
Balancing Rotating Parts
and Assemblies.
repaired or rebuilt at the same time and stored under the
TB 750-236
same conditions.
the Maintenance of Army
Material.
(3) Lot size. The lot size is the total number
TM 11-5523
Amplifier AM-186A/FR (TO 16-
of individual like items in the lot that is to be inspected.
35AM-186-5).
b. Sampling Procedure.
TM 11-5525
AF Amplifier AM-243/U and
(1) Sample selection.
Select samples of
AM243A/U (TO-16-
35AM243-5).
materiel in a way which will assure that each unit in the
TM 11-5536
lot has an equal chance of being selected. Biased
AM-245A/U.
methods, such as selecting items from the same
TM 11-5895-216-24
Organizational and Field
position in a container, pallets, or stacks; taking items all
Maintenance Manual:
from one location; or selecting items that appear
defective, will not be used.
Receiving Set AN/ALR-8.
TM 38-750
Army Equipment Record
(2) Sample size. Use table I of MIL-STD-
Procedures.
105D, General Inspection Level II, to obtain the sample
size code letter, and table II-A of MIL-STD-105D to
obtain the sample size using the storage quality levels
*This REP publication may be obtained from
shown in (3) below.
Commanding General, U.S. Army Electronics Com-
(3) Storage quality levels (SQL).
mand, ATTN: AMSEL-ME-NMP-PS, Fort Monmouth,
N.J. 07703.
(a) Mechanical-visual inspection: criti-
cal SQL 1.0 percent; major SQL 2.5 percent; minor SQL
5. Other Directives.
10 percent.
(b) Electrical: Critical SQL 1.0 percent;
Publication
Title
AR 795-17
General Policies and Principles
major SQL 2.5 percent.
for Furnishing Army
(c) Preservation, packaging, packing,
Materiel on a Grant Aid
and marking: major SQL4.0 percent; minor SQL 10
Basis.
percent.
(d) The acceptance or reject number
AR 795-204
General Policies and Principles
for Furnishing Defense
for the above SQL's shall be the same as those shown
Articles and Services on a
for comparable acceptance quality levels (AQL's) in
Sale or Loan Basis.
table II-A of MIL-STD-105D.
c. Inspection Requirements.
The following
6. Inspection Criteria.
mechanical-visual inspections shall be performed:
a. Lot Criteria.
(1) Inspect case for physical damage,
(1) Lot definition. A lot is defined as a group
of like items from which a sample is to be drawn and
condition, and finish.
inspected to determine conformance with the
(2) Inspect all controls and switches for
acceptability criteria. The following are examples:
proper operation and loose or missing hardware.
(a) A group of like items in storage
(3) Inspect all connectors, plugs, and cord
which were received in a shipment with the following
identical markings:
(4) Inspect assembly for physical damage,
1. Purchase order number.
condition, missing parts, foreign objects, and finish.
2. Date packaged or packed.
(5) Inspect cabling and wiring for potential
3. Depot certification stamp and
date.
and strain.
(b) A group of like items repaired or
(6) Inspect solder connections for missing
rebuilt by the Maintenance Division in one production
solder, cold solder, insufficient solder, excessive solder,
run.
and improper wrap.
(2) Lot formation.
The items shall be
5