TM 11-5821-333-30
3-10. TROUBLESHOOTING FLOWCHARTS. Continued
CHART 2
Display Reads FAIL8 (Sheet 3 of 5)
1. SET TEST ADAPTER:
DC
OFF
2. SET UUT:
PRESET
MAN
3. DISCONNECT TEST
CABLE W3 FROM UUT.
4. REMOVE CONTROL
PANEL (Al) FROM UUT.
5. USE DMM AND TEST
LEADS TO MEASURE RE-
SISTANCE BETWEEN
S4-C AND W2P1-1.
1. SET TEST ADAPTER:
DC
OFF
2. SET UUT:
IFM-RF PWR
NORM
3. DISCONNECT TEST
CABLE W3 FROM UUT.
4. REMOVE CONTROL
PANEL (A1) FROM UUT.
5. USE DMM AND TEST
LEADS TO MEASURE RE-
SISTANCE BETWEEN
W1P2-28 AND S1-C.
3-35