TM 11-5821-333-30
2-24. TROUBLESHOOTING FLOWCHARTS. Continued
CHART 34
RXMT Control Failure
1. SET UP USING FIG 2-8.
2. HOLD PTT(S8) ON TEST
ADAPTER AT REF.
3. USE LOGIC PROBE AT
XA5-62.
NOTE
1. See figure FO-10 for
location of test points.
2. W1P1 is the flex cable
connected to J1 on
backplane. W1P1-48
can be probed on top
of W1P1.
SWITCHING MODULE (A5)
IS BAD.
1. HOLD PTT(S8) ON TEST
ADAPTER AT REF.
2. USE LOGIC PROBE AT
W1P1-48. (NOTE 2)
CHASSIS (A11) IS BAD.
AMPL-OSC (A9) IS BAD.
2-142