TM 11-5821-333-30
2-24. TROUBLESHOOTING FLOWCHARTS. Continued
CHART 20
Load Failure (Sheet 1 of 4)
1. SET UP USING FIG 2-8.
2. SET TEST ADAPTER:
TEST EQUIPMENT
SELECTOR
SCOPE
TEST EQPT
INPUT
EXT
3. CONNECT AND TURN ON
FILL DEVICE. IF AN/ARC-
201, SET TO TRANSEC
VARIABLE (T1 OR T2) .
IF AN/ARC-201A, SET
TO HOPSET.
4. IF AN/ARC-201, SET UUT
FUNCTION SWITCH TO
LD-V. IF AN/ARC-201A,
SET TO LD.
5. WITH LOGIC PROBE AT
XA3-Q, PRESS H-Ld/0.
NOTE
See figure FO-10 for
location of test points.
2-116