TM 11-5821-333-30
2-24. TROUBLESHOOTING FLOWCHARTS. Continued
CHART 13
Receiver Sensitivity Test Failure (Sheet 1 of 6)
NOTE
See figure FO-10 for
1.
2.
3.
4.
5.
SET UP USING FIG 2-8.
SET UUT:
FUNCTION
SQ OFF
SET TEST ADAPTER:
TEST EQUIPMENT
SELECTOR
SCOPE
TEST EQPT
INPUT
EXT
S1
7
SET RF SIG GENERATOR:
FREQ
FAILED FREQ
LEVEL
-86 dBm
MODULATION INT, FM
MOD FREQ
1.0 kHz
DEVIATION
6.5 kHz
USE Xl PROBE AT
XA6-M. READ SCOPE
location of test points.
2-99